Description
X-radiograph Operator(s): Angela Chang

Duration of session: 30 mins

Total number of exposures: 2

Material Description: stone, metal (bronze)

Material thickness: various

Radiation source: Comet MXR-320/26 tube

CR plate type: Carestream Industrex Flex HR (white)

Exposure settings: 320kV 4.65mA 3mmFOC 50seconds 190cm focal distance

Filtration used: 3mm Cu

Screens used: 0.005 and 0.010 Pb

Set up/sequencing notes: one flat and one side view, separate file for each view with 6 edge viewing filter.

Scanning notes: laser power high, 12-bit logarithmic data scale, PMT 10, 50 micron scan resolution

Image manipulation notes: Industrex 6Edge filters as indicated